How to Do Fluorescent Liquid Penetrant Testing

  •  

Learn about the penetrant inspection method of nondestructive testing, including basic steps for NDT with an AMS 2644 Type 1 water washable penetrant

 

 

Just like all nondestructive testing methods, the results of a penetrant inspection are only reliable if the inspection is performed accurately and consistently.

In this video Magnaflux’s Brian Batteiger goes through the common steps of liquid penetrant testing as outlined in ASTM E1417: Standard Practice for Liquid Penetrant Testing.

  1. Surface preparation: It is important for the test surface to be clean, dry and free from any dirt, grease, paint or other materials which might interfere with the inspection.
     
  2. Penetrant application: Liquid penetrant can be applied to the test surface by dipping, brushing or spraying.
     
  3. Penetrant dwell time: Penetrant needs to be given adequate time to enter any discontinuities. The dwell time will be determined by several parameters, including the type of penetrant, type of developer and type of defect needing to be found.
     
  4. Excess penetrant removal: Penetrant remaining on the surface needs to be carefully removed while not disturbing the penetrant which has seeped into any discontinuities. Depending on the type of remover method, the part may need to be dried in an oven after the excess penetrant is removed.
     
  5. Developer application: A thin, even layer of developer is applied to draw out the penetrant in the discontinuity to the surface to form indications. The developing time will vary depending on the penetrant, type of developer and type of flaws.
     
  6. Inspection: The part is evaluated under the appropriate lighting conditions for indications and the appropriate steps taken to interpret and document any findings.
     
  7. Postcleaning: Parts are cleaned after inspection to remove any remaining develop and penetrant.

 

This is meant to provide a general overview of a typical LPI process; all NDT testing must be performed in accordance with the prescribed specifications or test procedures.

Want to stay up on the latest NDT insights and articles from Magnaflux? Subscribe to Magnaflux updates get fresh news delivered to your inbox.

Please wait while we gather your results.

Related Blog Posts

Benefits of Developer

Benefits of Using Developer During Liquid Penetrant Inspection [Case Study]

Learn how a automotive manufacturer increased indication detection in visible and UV light with developer.

Read More...

Liquid Penetrant in Dip Tank

How to Maintain Penetrant Testing System Performance

Learn how liquid penetrant testing products lose performance over time and what to do to ensure penetrant test reliability.

Read More...

Case Study – Comparison of penetrant inspection and eddy current testing on a corroded test sample

Our customer is an aerospace MRO (maintenance, repair and operations) company based in the UK, with an aerospace training college. Part of their training includes teaching students about NDT capabilities within the aerospace sector, identifying the strengths/weaknesses and applicability of different NDT inspection techniques.

Read More...

Magnetic Particle Crack Comparison

How Brightness and Contrast Impact NDT Inspections

How perception and vision can have a significant impact on probability of detection in non-destructive testing inspections.

Read More...

Dye Penetrant Testing on Pipe

How Low Temperatures Impact Dye Penetrant Testing

Learn how lower inspection temperatures affect the performance of dye penetrant testing cleaners, penetrant and developers

Read More...

Magnaflux Dye Penetrant Testing

How to Do Visible Dye Penetrant Testing [Video]

Watch an overview of the dye penetrant testing method according to ASTM E1417, including basic steps for NDT with an AMS 2644 Type 2 penetrant.

Read More...

ASTM E1417: Key Changes and Updates

ASTM E1417: Key Changes and Updates

The next revision of ASTM E1417 has been published, and a lot is changing. Here are several changes that you should be aware of.

Read More...

Why Penetrant Removability is Important, Not Just Sensitivity

Why Penetrant Removability is Important, Not Just Sensitivity

High quality fluorescent liquid penetrant inspections require strong removability combined with strong sensitivity to deliver clear, crisp indications

Read More...

4 Level III Daily Responsibilities

4 Level III Daily Responsibilities

Defining the different types of Level IIIs and some aspects of what their job entails

Read More...

What Do I Do If My Penetrant Freezes!?

What Do I Do If My Penetrant Freezes!?

Discover what mixing or testing could be required to return a penetrant to its original state once it has frozen

Read More...

What Value Does ISO 9001 Add?

What Value Does ISO 9001 Add?

Learn how ISO 9001 affects the NDT materials you use, therefore affecting your quality management system

Read More...

5 Things to Consider When Choosing a Mag Particle Yoke [Checklist]

4 Habits of NDT Aerosol Safe Handling

Safety is a make-or-break factor in a technician's world – we list details around hazards, storage, recycling, and shipping of NDT aerosols

Read More...

NADCAP and Known Defect Standards

Understanding Nadcap System Performance Check and Known Defect Standards

Properly demonstrating the system performance check was the #2 Nadcap audit finding for penetrant systems. What do you need to do to comply?

Read More...

Learn about the available properties of developers

Does Developer Dry Time Impact Indication Strength?

Learn about the available properties of developers and the relationship between dwell time and inspection quality

Read More...

Success with the Right Precleaning

Prepare for Penetrant Testing Success with the Right Precleaning

Learn why proper precleaning before liquid penetrant inspections can make or break your nondestructive testing results

Read More...

AMS 2644 Penetrant Sensitivity Levels

A Guide to AMS 2644 Penetrant Sensitivity Levels

Understand fluorescent liquid penetrant sensitivity levels and how to find the right one for your application

Read More...

Protective Armor Inspection with Zyglo Penetrant [Case Study]

Case Study - Protective Armor Inspection with ZYGLO Penetrant

In this case study, we show how an armor solutions provider increased quality control on a semi-porous surface with ZL-19

Read More...

automotive suspension system

Case Study – Use of ZYGLO® ZL-60C for the inspection of automotive suspension systems

Case Study – Use of ZYGLO® ZL-60C for the inspection of automotive suspension systems

Read More...

Liquid penetrants for leak detection of ventilation systems

Case Study - Using Fluorescent Penetrant for Ventilation System Leak Detention

Learn how to look at the recommended actions associated with the chemical risk assessment.

Read More...

Magnaflux Penetrant Inspection

Case Study - Higher Sensitivity Penetrant Improves Inspection Quality

In this case study, we help an aerospace customer improve inspection quality and consistency with two Magnaflux penetrants

Read More...

Magnaflux Penetrant Inspection

Case Study - Understanding Type-, Batch- and In-Use-Testing for Liquid Penetrants

Learn the differences between type testing, batch testing and in-use testing for NDT liquid penetrants.

Read More...

Case Study – Use of SPOTCHECK® SKL-WP2 for inspecting welded fabrications

Case Study – Use of SPOTCHECK® SKL-WP2 for inspecting welded fabrications

Read More...

Case Study – Use of non-aqueous developers containing propan-2-ol

Case Study – Use of non-aqueous developers containing propan-2-ol

Read More...

Case Study – Use of SPOTCHECK SKL-SP2 for medical packaging inspection

Case Study – Use of SPOTCHECK SKL-SP2 for medical packaging inspection

Read More...

Magnaflux Penetrant Testing

Exposing 10 Common Misunderstandings about Penetrant Testing

We reveal common misperceptions about liquid penetrant inspection we’ve seen in the field in recent years

Read More...

10 erreurs récurrentes rencontrées dans le contrôle par ressuage

10 erreurs récurrentes rencontrées dans le contrôle par ressuage

10 erreurs récurrentes rencontrées dans le contrôle par ressuage

Read More...

ASTM E1417 : Principaux changements et mises à jour

ASTM E1417 : Principaux changements et mises à jour

La nouvelle révision de l’ASTM E1417 a été publiée et beaucoup de choses changent. Voici plusieurs changements dont vous devriez avoir connaissances.

Read More...

Inspección por Líquidos Penetrantes

Exponiendo 10 malentendidos comunes sobre las pruebas penetrantes

En el siguiente artículo revelamos las percepciones erróneas más comunes sobre la inspección por líquidos penetrantes

Read More...

Subscribe to Magnaflux NDT Blogs:

Magnaflux

Faraday Road, South Dorcan Industrial Estate
Swindon, Wiltshire, SN3 5HE, UK
Telephone: +44 (0)1793 524566
Contact Magnaflux Customer Service

Magnaflux, A Division of ITW Limited   VAT number: GB 531 8325 59

Select Your Country North America Mexico Brazil China Europe India New Zealand, Australia, Japan, Southeast Asia
© 2024 Magnaflux - All Rights Reserved.
top