ZL-60C

Level 2 Water Washable Fluorescent Penetrant

Developed for testing rough machined surfaces, ZL-60C fluorescent water-removeable penetrant is ideal for finding indications in castings, forgings, extrusions and rough surfaces.

This medium-sensitivity penetrant washes off parts quickly and easily, leaving less fluorescent background - even on rough surfaces - for clearer indications and better inspection reliability. Broad specification compliance further increase this penetrants flexibility.

ZL-60C has excellent alloy compatibility and is safe to use on most engineering and aerospace materials, including aluminum, steel, nickel and titanium.

Recommended developers are ZP-4B dry powder, SKD-S2 or ZP-9F solvent-based or ZP-5B water based.

Improve indication detection

  • Makes indications stand out more by easily washing excess penetrant off with water.
  • Reduces background fluorescence, even on rough surfaces

Maximise application versatility

  • Ideal for an extensive variety of part types due to Level 2 sensitivity
  • Universal specification conformance and fast, even surface wetting

Affordable performance

  • Drives value at each step of the inspection process
  • Quickly apply penetrant with high surface wetting
  • Easily wash off with water
  • Use less penetrant over time because of lower drag-out and slower evaporation

Maximise operator comfort and safety

  • Promotes better inspection quality by providing the operator with a more comfortable work environment
  • Reduces discomfort from strong odours

Ordering Information

Aerosol (case of 10)008A008

25 litres056C205

200 litres056C206

Product Properties

NDT TypeFluorescent Penetrant Testing

Penetrant TypeType 1

Fluorescent Penetrant SensitivityLevel 2 - Medium Sensitivity

Penetrant MethodsMethod A, Method C

Removal TypeWater Washable

Required EquipmentUV light source

Applications

Ideal ApplicationAerospace alloys, Aluminum, Castings, Extrusions, Forgings, Machined components, Nickel, Rough surfaces, Steel, Titanium, Welds

Defect ExamplesCold shuts, Cracks, Delamination, Laps, Porosity, Seams

Compliance

StandardsAMS 2644, ASME BPVC, ASTM E1417/E1417M, ASTM E165/E165M-18, ISO 3452-2, MIL-STD-2132, Pratt & Whitney PMC 4350, Rolls Royce RRP 58003 (CSS 232), SAFRAN Pr 5000/In 5000

Resources

Related Products

  • ZL-15B

    ZL-15B

    ZL-15B Level 1/2 water washable fluorescent penetrant for Method A and C liquid penetrant testing

  • ZL-19

    ZL-19

    ZL-19 Level 1 water washable fluorescent penetrant for Method A/C liquid penetrant testing

  • ZL-60D

    ZL-60D

    ZL-60D Level 2 water washable fluorescent penetrant for Method A/C liquid penetrant testing

  • ZL-67B

    ZL-67B

    ZL-67B Level 3 water washable fluorescent penetrant for Method A/C liquid penetrant testing

  • ZL-56

    ZL-56

    ZL-56 Level 4 water washable fluorescent penetrant for Type 1, Method A and Method C liquid penetrant testing

  • EV6000

    EV6000

    EV6000 portable, hand-held LED UV lamp for fluorescent PT and MT

  • ST700

    ST700

    ST700 LED UV-A flood lamp for black light inspection

Subscribe to Magnaflux NDT Blogs:

Select Your Country North America Mexico Brazil China Europe India New Zealand, Australia, Japan, Southeast Asia
© 2024 Magnaflux - All Rights Reserved.
top