1. Check the condition of the yoke before each use 

Check the power cord and switch to make sure they're in good condition. Check that the legs can bend to conform to the inspection surface. Check the feet to make sure they can make even contact with the inspection surface. The more contact area, the better.  
 

 

2. Use a calibrated test weight to verify yoke strength

An AC yoke must lift 10 lb. / 4.5 kg, and a DC yoke must lift 50 lb. / 22.7 kg. Using just any piece of steel for the dead weight check can create a hazard for the operator; if the weight is not balanced it could slip off the yoke and drop. Calibrated test weights include alignment features to keep the weight balanced on the yoke, allowing you to perform the dead weight check safely. 

 
3. Follow the rated duty cycle  

The typical magnetic yoke has a 50% duty cycle with a maximum on time of 2 minutes. That means the yoke can be energized for up to 2 minutes continuously but would need to rest for the same amount of time afterward to prevent overheating. Exceeding the duty cycle can create a hazard for the operator and risk permanent damage to the yoke. 
 
 

4. Never switch between AC and DC modes while the yoke is energized 

Yokes are powerful electromagnets, and they carry large inductive loads. If an AC/DC yoke is switched from AC mode to DC mode (or from DC to AC) while the yoke is turned on, the feedback of the inductive load could permanently damage the internal components. Use caution when performing both AC and DC inspections to avoid accidental damage. 
 
 

5. Clean the legs and feet after use 

The legs and feet of yokes are steel laminations, and magnetic particles can become trapped in the joints. To keep the yoke in good working order for future use, clean out any trapped particles or dirt before storage. 

 

Watch how the Y-2 AC electromagnetic yoke has been designed to improve productivity and reduce operator arm and wrist fatigue here.

 

Published October 29, 2019

Please wait while we gather your results.

Related Blog Posts

Magnetic Particle Inspection Demo

How to Do Visible Magnetic Particle Inspections

See an overview of visible, dry-method magnetic particle inspection method according to ASTM E1444.

Read More...

The most common incorrect assumptions about magnetic particle inspection

10 Misunderstandings about Magnetic Particle Testing

This article discusses the most common incorrect assumptions about magnetic particle inspection and gives you some solutions to combat these misunderstandings

Read More...

Subscribe to Magnaflux News:

Magnaflux

155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe India New Zealand, Australia, Japan, Southeast Asia
© 2024 Magnaflux - All Rights Reserved.
top